GENERAL: Config Loaded
Flag to facilitate configuration loading control from Modbus master.
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |
| ADDR 0 |
Config Loaded |
| REGISTER GROUP | GENERAL |
| REGISTER ADDRESS | 0 |
| POSITION / BIT SIZE | 0 / 1 |
| ACCESS | R |
It is set to 0 when the device boots up. It is automatically set after the CONFIG_A and CONFIG_B address spaces are written.